the concrete mixing plant to improve the efficiency of the method

Concrete mixing plant in the concrete mixing plant in a credible position I believe we all know, while the concrete mixing plant in the course of work will encounter a variety of unexpected problems, such as the sudden stop turning, the consequences will be Not only will affect the quality of concrete, but also delay the progress of the project, to the user to bring greater trouble. At the same time, due to the neglect of the production staff, most of the concrete mixing plant can not do our daily requirements for daily maintenance work, here we give you a brief description of what you are using the concrete mixing plant The process more handy, while the concrete mixing plant can play to its greatest role.

the concrete mixing plant to improve the efficiency of the method
the concrete mixing plant to improve the efficiency of the method

Encountered a sudden concrete mixing plant to stop running:

1. Adjust the machine load
If the concrete mixing plant exceeds the normal load, it will slow the stirring shaft. If the load is too large, it will cause the stirring shaft to stop or the stirring shaft will bend. Then, only the amount of feed will be adjusted, the excess material will be discharged, Stirring the shaft to rotate the load.
2. Clear foreign matter
When the concrete mixing plant mixing blades or side blades and the inner wall of the tank has a large foreign body, especially the stones, will also cause the stirring shaft to stop, the reason to be able to deposit foreign matter, is the concrete mixing plant mixing blades or side leaves and The gap between the inner wall of the tank is too large. Side leaves and the inner wall of the stuck material, the mixing shaft before the stop will often have sharp harsh friction sound, this happens, the need to immediately stop the inspection, manual removal of foreign body, re-adjust the concrete mixing plant leaves or side blades And the gap between the inner wall of the tank, if necessary, can be washed with water.
3. Tension motor drive belt
Concrete mixing plant The motor drive belt is too loose and can cause the mixing shaft of the concrete mixing plant to rotate slowly or stop the rotation, because the motor drive belt is too loose, resulting in insufficient power transmission. At this point only after the adjustment of the concrete mixing plant to adjust the tension of the motor belt can be.
In addition, we will introduce you to some of the usual maintenance of concrete mixing plant tips, you can also look at the same time, in order to protect the effectiveness of concrete mixing plant operations.
1, concrete mixing plant before the daily work must check the lubrication of the oil and circuit and control equipment, and as required filling lubricants;
2, concrete mixing plant must ensure that the concrete mixing plant body clean, remove the body of dirt and obstacles;
3, the daily work must check whether the transmission clutch and brake is flexible and reliable, whether the damage to the rope, the track pulley is good, there are obstacles around the various parts of the lubrication and so on;
4, the mixer must be implemented two leakage protection, power supply after work connected, must be carefully checked, after the empty test that qualified, before use;
5, the concrete mixing plant before the daily work, in the mixing tube plus water idle for 1 to 2 seconds, while checking the clutch and brake device reliability,
Concrete mixing plant in the daily use of the process encountered by the user all kinds of problems, if the solution can be resolved in advance on the timely solution, in most cases are a long past the accumulation of small problems caused by a significant loss, so we This appeal to users not to lose big, affecting the progress of the entire work.